Home › Products and references / Offices /  Nidec ASI

Reference
Nidec ASI

Description

Purchasing Office Building


Technical characteristics of the prefabricated Purchasing Office

Type Modular pre-engineered building
Structure Galvanized steel structure

Wall
Roof
Outer roof

sandwich panel mm 100 thick PIR (rigid expanded polyisocyanurate)
sandwich panel mm 50+40 thick PIR (rigid expanded polyisocyanurate)
sandwich panel 50+40 thick with two sloping sides and ventilated under-roof
Doors&Windows Aluminum profiles powder coated with safety glazing
Floor Technical access floor UNIFLAIR 60x60 floor tiles calcium sulfate A30 raised height 30 cm
False ceiling Armstrong mineral fiber white color, suspended ceiling squares 60x60 soundproofing
Paint Powder coating RAL 9010 interiors, RAL 9006 on the outside
System Lighting system anti-glare, emergency lights
HVAC Electrical system 230/400 V, emergency lighting, grounding system copper bar 200 mm²


Technical Specifications

Type Modular pre-engineered building
Structure galvanized steel structure
Wall&Roof sandwich panel mm 100 thick mineral wool with inner side micro perforated
Doors&Windows Aluminum profiles powder coated
Glazing Special acoustic glazing 44.1/ 12/33.1 soundproof high performance
Floor Technical access floor UNIFLAIR 60x60 floor tiles calcium sulfate A30 raised height 30 cm
False Ceiling Armstrong mineral fiber white color, suspended ceiling squares 60x60 soundproofing
Paint Powder coating RAL 9010 interiors, RAL 9006 on the outside
Systems Electrical system 230/400 V, emergency lighting, grounding system copper bar 200 mm²
HVAC air conditioning split system, SAMSUNG 3,5 Kw